Step 3Star or Delta windings
Simplified explanation is that star gives more voltage and delta gives more amps for a given rpm.
Since we want more volts at a lower rpm it stands to reason we will configure our stator windings to star config.
If your stator had only 3 connection wires with 2 wires joined on each connection, then you would have a delta connected stator.