Our master bedroom is always either cold in the winter or hot in the summer. The fact that the builder messed up by installing just one register in the room and the room itself is right above the garage doesn't help either.

Using a digital thermometer I was able to determine that the temperature of the air coming in was half that of the hottest register in the house (obviously this is for the winter case), and the airflow was barely there.



My solution was to install a booster fan.

The process was not all that complicated and this job can be accomplished by anyone with some basic electrical skills and some tools you can buy at local dollar store.

Was it worth it? The answer is YES. Can it be done better? Yes but not by much. I'm sure some people out there who are familiar with how a furnace works will be able to come up with a better way in regards to how to control the booster fan, like using a pressure switch or choose other outputs on the controller furnace board. In my case, I just went with what worked for me and what I felt was safe from a functional point of view and liability point of view.


If any good recommendations are made here (and they are easy to implement in my current setup) I will try to include them in the overall design for other users' benefit so feel free to contribute.

I should also mention that this installation deals with electricity and electrical connection which means you might need a permit but most of all YOU NEED TO PUT SAFETY FIRST also, don’t forget your safety goggles.
 
Remove these adsRemove these ads by Signing Up

Step 1: The fan, the duct and what needs to happen

Picture of The fan, the duct and what needs to happen
IMG_1726_booster_fan_overview.jpg
IMG_1730_booster_fan_next_2_duct.jpg
In this step, I'm going to explain the theory.

So here we go.

The booster fan is installed in line with the existing duct that goes to the register for which you want to increase the air flow. The fan I got has two speeds one for 200cfm and 300cfm.

The power to the fan has to be turned on and off when the furnace is on or off. In my case I used a relay that is energized by the controller board (will get into that later).

There are furnaces that have just one speed for the blower or more than one speed, they may also have separate connections for Heat and Cold (aka A/C). You will need to indentify which connection works best for you.
In my current configuration, the fan only comes on when the Heat is on. Eventually I will use a 2nd relay to power the fan when the A/C is on or maybe a presure switch but given that I can get a relay for $8 vs almost $40 for a pressure switch I think I'll go with a relay.

Optional you can install a regular switch to disable the fan in case it becomes noise later on, etc. It's just good to have it and it's not going to cost you more than $5 to do it anyway.

So in a nut shell, here is how it works, the furnace comes on and the inducer motor kicks in, after a set delay the blower motor starts up, as soon as that happens, the relay coil is energized and switches on the power to the fan. When the blower is turned off by the controller board the relay will also switch off the power to the fan.

Step 2: The parts and tools

Well, obviously, you will need a booster fan. I got mine for $30 (on sale) from Pricess Auto
www.princessauto.com/farm/electrical/fans/0770071-2-speed-6-duct-booster-fan

I got the relay from Eastern Refrigeration for about $8
www.easternref.ca

The rest of the stuff I already had it or got from Home Depot.

Here's what you'll need (prices are approximate):

* 15A 14-2 (white) wire - you don't need to buy a spool, you can by a "pack" or just ask them to cut it for you. I already had a spool so, sorry, no price.
* Armored cable. I need about 15ft - around $19
* 16 gauge conductor black and white, 3 feet each.

* Junction boxes - see pictures for more info. They are usually around $3-4. You will need one to connect the fan. Most likely your local code will require you to have all non low voltage connections made in a junction box. I used a shallow receptacle box for the connection at the fan end and a regular one for the "disable/enable" switch. For the connection in the furnace I used a square box just to have more room. Next time I will look for a bigger box that will accommodate 2 relays. As a side note, all connections have to be accessible in case there is an electrical problem.  This means that if you ever finish your basement and your junction box will be hidden by drywall, you have to cut the drywall and have some sort of access door (panel door). This is not only good practice but it's also electrical code.


* Disconnects
* Marrettes for wire connections pack of 15 $2 (aka, wire nuts or wire connectors)
* Electrician's tape $.50
* Wire staples
* Wire clamp
* Zip ties
* Switch (optional) $.50-2.50
* Aluminum tape (optional)
* Shrink tube (optional)
* 3" wood screws
* 1/2" bolt and nut to secure the box to the furnace (optional)

Tools
* Hammer
* Drill
* Snips
* Knife
* Drill bits and preferably a step bit
* Crimp tool
* Wire cutters

* Safety goggles
* Meter (optional but you will need it if you can't find the terminals on the controller board)

 

At this point, you should test the booster fan and the relay by powering them. Technically you need to apply power on the right connectors/terminals. By the time you are done with this Instructable, you should have a good idea how it should be done. If you still feel like you don’t know how to do it, just Google :how to test a relay” or “how to test a fan”/ Obviously, the fan should turn and the relay should be energized, using a meter across the connection terminals (in my case terminals 2 and 4) you should get a 0 Ohms reading or if you have a continuity feature on your meter you should hear a beep as long as your probe leads are in contact with the terminals.

Step 3: The relay connection

Picture of The relay connection

For those not familiar with relays, here is a quick intro.

A relay is nothing more than a switch that is activated by applying power to two terminals connected to the coil inside the relay (aka energizing the coil). When the coil is energized, it acts like a magnet (this is how all electromagnets work and a relay is no different). The electromagnetic field attracts the contact blade inside the relay; this is pretty much the equivalent of flipping the switch on.

When there is no power to the coil, the contact blade is in its normal position. The word normal has not been chosen at random.

Relays have two kinds of contacts NC and NO. The NC stands for Normally Closed and NO stands for Normally Open. The logic is simple, when the contact blade is in its normal (non-powered) position the contact can be NC or NO. There are relays that have only one kind of contact (NC or NO) or both in which case you pick the connection that suits your application. An NC connection means that the switch is on when there is no power to the coil and the opposite is NO. One easy way to remember which one's which is like this: when a switch in a circuit is closed it means that it closes the circuit just like a complete circle (you can go around that circle forever, closed circuit), when it's open it's like the wires are up in the air and the current has nowhere to go (somebody took an eraser to our circle and now the circle is broken, sooner or later you will hit an end).



All relays have some specifications (usually, printed right on the case): coil voltage, contacts rating (voltage and current) and post (terminal) diagram.

Coil voltage shows you what kind of power is needed to energize the relay. This could be 120V AV, 240V AC, 12V DC, 24V DC, etc. In this instructable we will be using a 120V AC relay.

The contacts rating tells you what the relay can handle. If it says 120V/10A it means you can use it in a circuit that will switch on and off a load that uses no more than 120V at a pick current of 10A. Can you use this to switch a 12V/10mA load? Of course but why would you use a higher rated relay like that when you could use a smaller and cheaper one. The point here is: do not use a relay that can't handle the load.



Lucky for us, the booster fan is not a big load. I used a big relay only because I found it for $8.

Step 4: Installing the fan in the duct

Picture of Installing the fan in the duct
IMG_1730_booster_fan_next_2_duct.jpg
IMG_1733_Snips.jpg
IMG_1734_Booster_In_Duct.jpg

This can be tricky, especially if the duct is behind the ceiling. In my case, the basement is not finished and I had access to the duct but still I had to have help to remove a section of the duct.

First thing you need to do is to identify the correct duct. It would be a real pain in the rear side to install this in the wrong duct.

Start by removing the aluminum tape if you have it. The easiest way to cut it is to get a piece of wire (I used some MIG welding wire) and make a knot in it, wrap it around the duct and in a back and forth motion "cut" the aluminum tape on top of the duct (where you don't have access to cut it with a knife), the knot in the wire will tear the tape. For the bottom, just use a knife. You can get a better idea of what I'm talking about if you look at the picture below.



Locate the screws that hold the duct segments together and loosen the segment and work one of them out.
Once you have one out, open it up by undoing the seam, rest the fan on it and make a mark from the clean edge of the duct to the point on the fan where it just starts to get "wrinkled" (that part will go inside the duct after you cut it to the new length) - see the picture.

At this point you need to figure out if the fan should go first into the duct that hasn't been removed or the one you just cut. This decision is based on accessibility.

You can drill some pilot holes for the screws or just see if you can actually make the self tapping screws go in without the pilot hole.

Step 5: Running the wire to the furnace

Picture of Running the wire to the furnace
IMG_1754_Booster_Fan_Finished.jpg

Find a place where you want to enable/disable switch and run the 14-2 cable to the fan.

Pull the cable in the connection box, about 4", remove the plastic sheathing and strip the end of the wires about 1/2". Secure the cable by tightening the clamp in the box.



Do the same for the fan wires. Twist together the stripped ends of common wire with the white wire and then turning clockwise twist the marrette on the ends.
Connect the black wire to yellow or red following the procedure above.

The bare wire and the ground wire go together and they are attached to the box. You can either connect them directly to the box or use a "pig tail" bare wire with one end connected to the box and the other to the bare wire coming from the furnace and the ground coming from the fan.

Note:
The black wire is always the live wire (by code). One way to remember which one is live is that death is black and if you are messing around with a live wire the black death is just around the corner.
If you ever need to use a different color wire just wrap a piece of black electrician's tape on it to indicate that the wire is the live one.


Pull the 14-2 in the switch box and prep it for hooking it up to the switch by removing the plastic sheathing and striping the ends.

Staple the cable once you're done with the connections.

Step 6: Moving on to the controller

Picture of Moving on to the controller
Connection diagram.jpg
IMG_1735_Connection_diagram.jpg
IMG_1738_Control_Board.jpg
IMG_1736_Inducer_Motor.jpg

THINK SAFETY FIRST

Before you do anything else, turn the furnace power off. Most likely your furnace has a main switch, make sure it is in the off position.

Remove the furnace cover.

Locate the connection diagram on the inside of the cover. I will talk about it in a second. For now I want to focus on the overall connection diagram for the booster fan.


If you take a look at the fan diagram below you will notice some of the parts I've been talking about, booster fan, relay, blower motor, etc.

One thing to keep in mind is that all the info here refers to MY furnace, your connection diagram might be different but the theory behind all this is the same.

OK, let's dissect this diagram.
The dots represent connection points in our circuit, they can be on the controller board, in a junction box, etc. More wires can go to those points, I've shown only the ones we care about.
Let's start with the blower motor. Like I mentioned before, I wanted the relay to be energized when the blower motor was on.  In this case, the HUM terminal has 120V when the motor is on HEAT, a separate circuit on the board takes care of the motor when A/C is used.
To cover the A/C scenario, I will add a separate relay connected to Common and A/C. The switch in the relay will be in parallel with the COLD switch. When energized, this relay will act just like the existing relay.

So this covers how the relay gets triggered.

 

Now, once the relay closes the circuit (again, closing the circuit means current can flow through it) power can be sent to the booster fan (assuming the enable/disable switch is also closing the circuit). There are two things you need to pay attention to here:

  1. power is sourced from L1
  2. the common contact point is really a common contact point.

 

You should be able to determine where Common and L1 (or whatever it’s called on your diagram) by examining the furnace connection diagram or using a volt meter and turning on the furnace (up the heat on your thermostat to make sure the furnace comes on). Make sure your L1 is not powered when the furnace is off.



In my case I had to create a Y cable for the L1 connection. There were no terminals available on the board so using some 167 gauge conductor I crimped one end with a female disconnect, soldered the other end to two other wires and using a piece of shrinking tube I insulated the connection (you can use electrician's tape). One of the two ends was crimped with male disconnect (so the disconnect that was hooked up to the board originally can be connected again) and the other end was crimped with a female disconnect for the terminals on the relay.

The rest of the connections were made with white or black 16 gauge wire using female disconnects.

This sounds complicated but once you get going and follow the connections you will get it.

The pictures below will help a lot to understand what needs to happen.

I should mention here that there is probably an easier way to turn the booster fan on but I don't know enough about how a furnace should work. A pressure switch will work but I'm happy with the relay solution even though I have to modify it later for A/C.

Step 7: Hook ups and testing

Using a large drill bit, drill a hole in the side of the furnace where the armored cable will come through.

A step drill bit will come in handy but you can do this with a dremel tool. I highly recommend the step bit. You can probably find one for less than $15, don't go nuts on specially coated step bits, just get something to finish the job.



At this point, it is a matter of hooking everything up.

Identify the connection points on the board, run the wires to the relay and connect everything up.

Check, double check and triple check your connection. You don't want to fry the controller board just because you made a "small" mistake like hooking L1 to Common in effect creating a short.



For all other connection not using a disconnect terminal just use the striped wire end and marrette technique explained in Step 5.

I should touch on how to cut the armor. Look at the picture. You will see that I bent the cable and as a result, the armor just "snapped" out. Using wire cutters (side/diagonal cutters) cut the metal strip. Be careful not to cut the wires or the insulation. This sounds complicated but believe me, once you bend the cable you will see what needs to be done.
After you cut the armor, trim the cut end so it doesn't slice the insulation and pull it out.
Run the end in the junction box and secure it with the clamp.

If you are not installing an enable/disable switch then you don't need the armored cable. In this case the 14-2 will go into the box.

If you are installing the switch then run the other end of the armored cable to the box where the switch is and make the necessary connections. Remember, the black wire will be connected to the switch, the white one will be connected to the 14-2 cable and the bare wires will be connected together and hooked up to box.

The pictures below will show where things are and what you need to do.

TESTING

When all connections are done, restore power to the furnace, crank up the heat on the thermostat, if you used a enable/disable switch make sure it is in the ON position and either push the interlock switch or tape it (don't forget to remove the tape when done).

At this point, after the blower motor kicks in you should hear the relay being energized (one click). Go to the register and inspect for higher air flow. At the thermostat either turn down the setting or just use the OFF position to turn off the furnace, when everything is off (there will be a delay) inspect the register again to make sure the fan is not on anymore.

Step 8: Wrap up and final thoughts

Picture of Wrap up and final thoughts
Connection diagram.jpg

If everything checks out OK, put the covers back on the furnace, junction box(s) and switches.

Wrap aluminum tape over the joints.


Final thoughts


-- Performance --
The airflow has increased by about 100% and the temperature by 30-40%, which really made a difference in our case.

You can hear the fan working so this is not silent solution but the noise is not bad plus it gives you an indication that the fan is not stuck.
The humming generated by the fan is actually therapeutic (at least for me it is).


-- Other thoughts --
Always put safety first, turn off power, use safety goggles, insulate exposed wires, etc.


Do not use a switch from the Dollar store, for about the same preice you can buy one from Home Depot or Lowes. Mine was bad and I had to do some troubleshooting. As a matter of fact, the instructions for the Dollar Store switch said to connect the black and white wires to the switch terminals which means to close the circuit between the live and neutral wires in effect creating a short-circuit, so be careful there.

Make sure all wires/connections are insulated properly.

If you are not comfortable working with electricity then don't do it, ask a friend or bring in an electrician to help you. electricity can and will kill you given the right circumstances.




Enjoy your new booster fan.


EltonC115 hours ago

Actually it all works out better for me that way. I can now plug the booster fan power supply into a 24 hour wall timer. The booster fan is for a room that is only occupied at night. This is a good option for others who want to do it like that.

I had everything wired and install only to find out I had a defective relay. I do not know if yours does the same but this relay whine so loud when energize, you can hear it from the floor above. I recheck the connection and everything was correct. I am going to get another and if it still does the same I might have to relocate it to inside the furnace like you did yours.

Thanks again.

F22-Raptor (author) yesterday
Thanks Elton. Use the relay as a switch, when the relay is energized, it will close the circuit regardless of where the power is coming from.
You should try to do the total amps to see if you are still within 15A. The furnace should have some sort of label giving you the total current consumption.
EltonC1yesterday

Raptor, my booster fan is only 0.7A but I have a powered humidifier and a EAC unit hook up to the board already. My furnace main blower is 1 HP (don't know the amp). I was thinking that's a lot going on in there already so I would prefer to have an outside source to powered the booster fan if possible. I just need the furnace to trigger it when the main blower comes on.

I ask cos in your write up you said, " Make sure your L1 is not powered when your furnace is off ". So, if my booster supply line is from an outside source instead of the L1, the line will always be powered regardless if the furnace is on or off. Just wasn't sure if the relay can be connected like that. Don't want to toast anything.

BTW the supply line for my furnace is 15A ( max per GDM installation guide ). Thank you for your good write up.

F22-Raptor (author) 3 days ago
Hi Elton, I'm not sure what the EAC is but if has power when the heat and cold is on then you can use it to activate the relay.
If you are concerned about the power drown by the booster you can source the power from a separate outlet, etc. my booster is not that powerful and the board looks like I'm t can handle the juice required to power it.
Take a look at the label and see what the power is, it my be listed as watts, e.g. 0.25W or the current it pulls, e.g. 0.5A. Your furnace is most likely on its own circuit of 20A or 30A, that's a lot o power to go around for the furnace a a small motor in the booster.

You should still check to make sure everything is ok, don't just take my word for it.

Feel free to post questions/comments here. I'll do my best help out.
EltonC14 days ago

Can I connect relay to EAC instead of HUM terminal? This way it will be energized on both HEAT or COOL when the blower comes on.

And the power source for the booster fan, does it have to be from the furnace board ( L1 in your case ) or can it be supplied from an outside 120v line. I ask because during heating the furnace is pulling a lot of load running main blower, induce draft blower, humidified, EAC etc...all through control board line. Will it be too much to add a booster fan to it.

bmiller911 month ago

Due to location in sub attic running control wire to relay would be a major task. Any bright ideas on sensor that I could attach to a relay that would sense airflow in duct?

cecil.johns13 months ago
Can you connect the duct blower straight to the hvac blower?
F22-Raptor (author)  cecil.johns13 months ago

You could. The reason I didn't do it was because I wanted to have complete isolation between the control board and my booster fan via the relay, I didn't hook it up to the blower because I was not sure how the blower and the relay would behave if both were energized from the same source.

Apparently, most control boards have a dedicated output that is on when the blower is on. I forget what is called. I might have mentioned it in one of my previous comments.

F22-Raptor (author) 9 months ago
I agree, Bill. When I did this, I couldn't figure out which terminal was the one for blower, hence the heat only option. I think in one of my comments I mentioned which terminal to use. Even if the booster fan comes on early, it is not a problem. It's not on for too long and it doesn't temperature. Maybe at some point when I have some spare time I'll do it right, that way, it will kick in when the AC is on as well.
Great write up! A couple of comments. As for picking up the relay control from the thermostat, your booster fan will come on when the tstat calls for heat. Not when the furnace finally warms up and is ready to deliver heat. Thats why the blower does not spin up right away. It takes time for the furnace to get hot. Otherwise the blower would be moving cold air. As for changing the fan speed with a dimmer, it might work to sme extent, but not properly, and will drastically reduce motor life. Motor speed on these is based on the frequency of the ac power coming in. Due to the laws of nature, reducing the voltage will just increase the current, and will overheat the motor windings and maybe your control relays and wiring.
csmillie1 year ago
Thanks for the great guide on installing the booster fan ( something I'm considering ). The only question I have is around your relay wiring. Did you consider using the R and G thermostat wires with a low voltage relay? It would seem to be easier to pickup the thermostat's request for the fan regardless of heating or cooling...

Also how to you find the noise? Did you need to insulate around it at all?
F22-Raptor (author)  csmillie1 year ago
I'm not sure how the thermostat interacts with the control board using those two wires. Maybe and HVAC guy/gal can help here. I was concerned that my adding a relay in that particular circuit might mess something up. If you look into it and it turns out it is a better option, please do share the info here. I know there is another output on the board that would power the relay regardless of setting (cold/heat) - I forget what it is called now. The other thing is that the thermostat, tells the board when the threshold has been reached/crossed but the board really turns the blower fan off a little while later to fully take advantage of any hot/cold air left in the system.
Personally, I'd still use the control board to turn on the buster fan.

The noise level is a little higher than what I want it to be but I got used to it. I am talking about the noise coming from the register. There is almost no noise where the buster fan is installed.
I can't tell is the register noise is high because of the increased airflow (I'm sure that is a factor too) or because of the noise coming from the motor through the ducts. I guess, if you want to eliminate any telegraphed noise, you could use some rubber connects (Home Depot sells them) to connect the motor to the ducts and avoid any motor noise or vibration.

One of these days, I'll measure the noise level and post it here. If I had to guess, I'd say it is twice as loud as an old fridge, not as loud as a regular dishwasher though.

I hope this info helps. Let us know what you find out about the R & G wires.
pjinst1 year ago
Just in time as I'm working on something similar. I've laid out my ducting with the booster fan and looking how to turn it on when heat/cool is called. So, just to clarify, the GREEN wire & WHITE (common) wire can actually energize a 24VAC relay to switch ON the booster fan? I've just inspected my thermostat's wiring and notice that the common wire is not connected (but present). Is common wire normally not connected with these digital thermostats?
dzip1 year ago
I bought exactly the same duct booster. The only problem I have with the unit is the noise. I'm considering installing a dimmer switch in the power run instead of a normal switch to see if there is a good trade off between noise and air flow. 250 cu ft per minute is a lot of air flow considering I'm heating a room of about 1200 cu foot. Thanks for the instructions.
F22-Raptor (author)  dzip1 year ago
That is a great idea. Be careful not to turn the dimmer all the way down. If the coils in the motor don't get enough juice to turn, you might short them.
seabirdbill2 years ago
Sorry for the delayed post. I finished wiring the fan using a 24VAC relay and the GRN (fan relay) and C(Common) leads from my thermostat. I did the actual wiring in the air handler since the duct and installed fan were located nearby. I installed the duct fan relay in a box near the fan. I pulled 120VAC from a nearby crawl space outlet. This serves a sun room that is at the end of the trunk. The thermostat gets it power from the 24v transformer in the air handler. The thermostat gets power from the transformer (the batteries are for programming backup and screen lights) and when the set temp calls for heat or cool a relay in the thermostat activates sending 24VAC via the GRN wire to the air handler fan relay. I connected the 24VAC duct relay to the GRN and C so that when the thermostat called for fan the duct fan would also activate. BTW, I have a single speed heat pump fan. This has been working great for me and the temperature in the sun room is tolerable. I got the 24 VAC relay from amazon. I included a scan of a thermostat schematic but it may not be readable. If you Google aprilaire 8346 thermostat wiring and look at page 9 of the pdf you will see what I tried to explain.
thermo.jpg
F22-Raptor (author)  seabirdbill2 years ago
Cool, thanks for the update.
seabirdbill2 years ago
Great instruction! Dont know if it was mentioned anywhere but I plan on installing the fan using a 24 VAC relay energized by the GRN fan relay from the thermostat switching the 120 VAC for the fan.
F22-Raptor (author)  seabirdbill2 years ago
Hmmm, I'm not sure how that is going to work out. I have a digital thermostat powered by 3 (I think) AA batteries. Energizing the replay from those batteries would drain them quickly.
I don't know enough about the thermostat and the control board from the furnace/AC communicate. From your comment, it sounds like there is power control on a 24V circuit coming from the thermostat.

Please post some details, it might simplify my solution and make the idea more appealing to people who are not comfortable "tapping" into the furnace/AC control board.
ewaldoh3 years ago
The reason for two speeds is that it is not difficult to get warm air to rise up to the upper rooms so a low speed will work normally.

Cold air from the AC is denser and not so easy to lift to upper rooms. Thus the higher fan speed
Spiff735 years ago
How greatly has that improved the temperature in your room?
F22-Raptor (author)  Spiff735 years ago
I checked the temperature last night with a digital thermometer (point and shot type) and it was ~106F/41C which is up about 30-40% from when I didn't have the fan. The air flow is almost 100% increase.
I compared the temperature to two other registers, one very close to the furnace and one a little closer to the furnace than the register in our bedroom. Here are the readings for the two:
- register very close to furnace: 122F/50C
- the other register 90F/32C

The last register (90F/32C) should be warmer than the one in our bedroom given that it is a shorter length and does not go through the space between the garage ceiling and bedroom floor.

I will update the Instructable with info re. performance.
I have the exact situation as you had with a cold bedroom above a garage.
I would like to add one of these booster fans to the heat duct as well as to the cold air return duct. ( I added a cold air return as there was none previously. However the pull is very weak).

Is it possible to connect both to the fan blower?
Thanks.
F22-Raptor (author)  vinnyd133 years ago
The short answer is no. The two air pathways are separate plus you can't change the direction on the motors on demand. When you mount them you make sure they pull or push based on your needs.
It sounds like you will have to use a separate blower for the cold air return but have both blowers turned on and off by the same relay.

I'm not sure you really need one for the cold air return. I suggest you talk to and HVAC guy and see what he says.
Maybe other people here can shed some light on this.
Yes, I was going to use two booster fans. One for the heat duct, one for the cold air return. I guess I could use a pressure switch for the heat duct fan, and wire the one in the cold air return to the main furnace blower.

The cold air return that I added barely pulls at all, so it needs something to increase suction. Thats why I was thinking of a booster fan, in reverse.
F22-Raptor (author)  vinnyd133 years ago
Make sure you use a relay. That way you keep the two circuits separated electrically and avoid liability to a certain extent.
HI F22-Raptor,

Where on earth, but more specifically in the GTA, can a mere mortal purchase the relay you used for this project? Or its equivalent?

Eastern Refrigeration won't sell it to me because I'm not an HVAC tradesman.
WWG Totaline won't sell it to me for the same reason.
Seriously, I'm standing there looking at it, cash in hand, and...no sale. I couldn't even grease the guy. I'm assuming it's not some critical component in a nuclear device, so what's the problem I wonder.

Ebay sellers want US$30 just to ship it to me so I'm trying to avoid that route. Certainly someone in the GTA can supply this to a DIYer.

I've also tried Westburne-Ruddy, Nedco, and TES. No luck.

Thanks for any help. Other than the relay, I'm ready to go.


That is really strange. It's just a relay. When I got mine form Eastern Refrigeration I just walked in, told the guy I was looking for a relay and he got one for me.
Your best bet would be to go to Sayal (http://www.sayal.com) and go to their relay section. I got 3 relays from the Matheson Blvd. and Dixie Rd. store for about $7-8 about 3 week ago. They have lots of them. Your biggest problem will be finding the one you want. They have one aisle just for relays 5V, 6V, 12V, 115V, 240V etc. They also have solid state relays but they are more expensive and for this kind of application it doesn't make sense to use them. While you are at Sayal look for quick connect terminals, shrink tubing etc. You should buy 2 relays (heat and cold) and be done with it. When I did mine I wasn't sure how the whole thing was going to work out. Next year I'll do the cold relay as well.
Let me know if you need help, I work 10 mins from Matheson and Dixie.
Sayal has a store in Vaughan as well (check out their locations on their site), that one is 10 mins from where I live.
 Just curious, but why did you use a relay?

Couldn't you just drive the booster fan from the HUM connection point? Isn't it only energized with 115V when the blower motor is on?

That's a great question. It's something I should've covered in the Instructable. There are two reasons:
1. My controller has separate outputs for Heat and Cold and from what I'd read it sounded like there are separate windings in the blower motor (2 different speeds I guess). Later on, this will allow me to install a second relay that will be energized by the Cold circuit, that way, my fan will kick in when the AC is on as well.
2. Liability, if my fan is totally separated from the control board via a relay, then I don't have to worry about it damaging the control board if something happens on the fan side.

Also, the relay option will allow other people to control fans that are not 115V, say 24V. Obviously they will have to use a separate transformer or use the one that's already in the furnace but from a control point of view, using the relay keeps things segregated and safe.