Step 1: The no-transformer transformer.

Picture of The no-transformer transformer.
When we connected LEDs to AC transformers, the calculation we used was:

Vac / 3.3

to give us the number of LEDs we need to be able to properly handle the power without additional resistors and other parts.

What if we bypass the transformer completely and consider AC mains? In some ways it is simpler - the voltage from transformers could vary greatly with the load we put on it, whereas AC mains are much more stable.

If we use the 110v standard of the US, we first calculate the peak voltage, 1.4 * 110 = 156 and we can find the number of LEDs it can support:

156 / 3.3 = 47 LEDs

So, does that mean that if we put 47 LEDs in series, we can run the whole string directly off a 110v AC socket?

The answer is Yes! As long as we maintain the voltage across each LED at 3.5v or less, it will operate within its limits.

But then, let's not forget that for each positive cycle, there is a negative cycle! That means we need a mirror circuit like in (1).

Wow, that's an awful lot of bulbs!

However, if we add a blocking diode like in circuit (2), then we can safely operate our circuit. The 1N4003 is capable of handling 200 volts so is fine for US power.

For EU countries, the magic number is 103 LEDs (double if you want to use both cycles) and the diode for ckt (2) should be a 1N4004 or better.
1-40 of 86Next »
hagen210 months ago
I built this. I used 42 extra bright white leds with a 3.6 forward voltage. I built a 1N4003 diode bridge for rectification. Plugged it in. Worked great. At first. Then it started to smell. Then some of the lights started to flicker. 10 minutes later half of them were no longer lit. I unplugged it and plugged it back in and now it won't come on at all.

Isn't everyone going to have this same experience? Won't this just overheat the leds which are in such close proximity to each other. I wonder if building this in a bar instead of a square would help with heat dissipation?

Anyhow I'm not happy with the results.
qs (author)  hagen210 months ago
Built correctly, the circuit consumes only 4 watts, so power dissipation should not be a major issue. A thermal scanner in my testing indicated 75C operating temperature, well within the tolerance of the electrical components.

You mentioned that half the LEDs failed first, to be followed by the other half. This would instead suggest a wiring problem -- the LEDs have to be all connected IN SERIES, with the current flowing in the same direction as the rectified power.

Other things to watch out for would be a supply mains voltage substantially over 120v, as well as mixing LEDs of different colors.
WVvan2 years ago
Thanks for your LED postings. All are very informative.
qs (author)  WVvan2 years ago
Thank you.
wiraksana3 years ago
I know it's a little bit dated to ask. I plan to build one of your instructable. i have 2 questions.
If i used combination of white led and amber led (to soften the light), should i use your formula too? let say if i use 80% of the voltage for white led (3.3volts) and use the rest for amber led (2 volts).
can i use capacitor after bridge rectifier to minimize the flickering effect?
thank you.
maanhe3r3 years ago
Hello qs.
I commend and thank you on a very interesting and educational Instructable. I really like the way you try to teach the principles instead of just showing how to slap something together. Your style has inspired me to want to try building the circuit in sketch 3 / step 2.
My question: How many of the circuits as in sketch 3 step 2 can I connect safely to one 120V outlet? What is it I have to be careful of ( current, voltage, power, ?).
I'm looking to replace a tube fluorescent lamp in the kitchen and am thinking I will probable need 4 or 6 such circuits (?) to get an equivalent lighting effect.
qs (author)  maanhe3r3 years ago
A crude rule-of-thumb is to multiply the wattage of the LEDs by 5 to get the equivalent output of a fluorescent. However, if the light is in a single direction, the multiplier can be as high as 10, since the LED is naturally directional.

Here, if you are using 117v, then the 50 or so LEDs will dissipate about 4-watts, making them equivalent to a 20W tube; or a 40W one if aimed down from the ceiling. Running 240v in other countries will see about 10watts.
clchee3 years ago
For the circuit with AC Cap, does it matter if Live and Neutral was connected the other way round ? Just in case deliberately or accidentally someone swapped the L and N positions at the outlet.
qs (author)  clchee3 years ago
It doesn't matter which side is used, AS LONG AS YOU ADHERE TO STRICT HIGH-VOLTAGE PRECAUTIONS: Do not touch or adjust ANY part of the circuit if it is plugged in!
Dipankar3 years ago
Let me know if I am wrong.........

1.4 x 220v = 308
308 divided by 3.5 = 88
So 88 LED's on both sides without using a Bridge Rectifier.

positive cycle and negative cycle,
That means we have a mirror circuit with 88 + 88 LED's
Am I right?
qs (author)  Dipankar3 years ago
Yes, your calculations are right.

Coincidentally, Phillips has announce THEIR version of this 'big' light for 230v where they place 96 SMT (Surface mount) LEDs in series with a bridge rectifier. This allows the LEDs to run cooler and perhaps extend their life.
Philips230v LED2.jpg
Dipankar qs3 years ago
I think the Phillips SMT (Surface mount) LEDs will be costing hell of a lot of money?
qs (author)  Dipankar3 years ago
And you'd be right! No firm prices yet but bhey are claiming life in 10's if not 100-thousand hours and that a panel will save over $150 of electricity over their life.
Dipankar qs3 years ago
$150 of electricity over their life time is peanuts?
I would rather stick to the present cheap ones, cause if they give me 5 years my money is worth it.
Over 2 years has passed and my LED Chandelier is being used daily is still going strong without any LED's packing up. Isn't that something?
-shtoink-4 years ago
I am hoping that you might be able to verify that I am going about this the correct way. I'm not actually trying to drive LEDs right from the AC in the wall, but rather from an AC inverter meant to drive a CCFL for a small LCD picture frame. It's a 7 inch wide screen LCD. I would like to still be able to make use of the features for controlling the backlight-off timer built in to the device, but may not be able to if this isn't a good option. Before I go ahead with this, does it sound possible or should I look at using DC to drive the LEDs from another location on the board.

Here's what I measured: V AC is about 540V and the current is about 2.5 A.

I wasn't able to measure the frequency, but looked of the values of other DC-AD inverters and they ranged between 30 to 50 kHz.

Running through the calculations, I get X=38184 ohms and C=1.4E-10 F when using the 30 kHz frequency.
I know this reply is a bit dated, but in case anyone goes rummaging through the archives....
The answer is NO.
DO NOT attempt to run led's from the inverter output.
In actuality, you may have measured 540VAC, but due to the frequency put out, it may actually be producing over 1000volt, and your meter just not able to cope with the switching speed.

If you MUST use that control board, I'd suggest tapping into the circuit somewhere safe, and before the inverter.
To retain the most factory like operation, I'd personally remove the inverter, anbd tap into the former input locations to power my led circuit. but that's just me.
I should note that I did these calculations with the measured VAC*sqrt(2). Thinking about that now, it was probably not correct.

R = 540 / 0.02 = 27000

C = 1/(2*PI*30000*27000) = 1.96E-10

Those are most likely the values I need to use if this is something that might work.
budiyanto4 years ago
pak kalau diindonesia tegangan umumnya 220 volt bagaimana sama saja tidak skemanya atau beda terima kasih
If the leds are 100ma instead of 20ma would the value of R change? The purpose of R is to protect against spikes in the current? How id the value of R calculated? Thanks
qs (author)  elementarywatts4 years ago
For anything other than 20mA LEDs, it is not advisable to use this method to reduce the voltage: use a transformer (See part 1) or a direct-connect switchmode system as in Part 4 of this series.
If I use a bridge rectifier the dc rms output voltage is lower than the input AC voltage. Would I still use the rule to increase the DC V rms measurement by 1.4 for the purpose of determining the amount of leds per string? If I install a capacitor 100uF 200v on the DC side the voltage goes up. Do I need a capacitor? Would that increase overhead at the line source? Using the same method as you I am making a spotlight with some 400 leds + or - with serial / parallel. If I do this correctly would I expect the life of the leds to be long as they are rated 100,000 hrs.? Thanks 3.5v 20ma 5mm I would not like a lot of overhead only to drive these leds.
qs (author)  elementarywatts5 years ago
Are you saying that by adding a 100uF capacitor the measured voltage goes up? That is probably because you are using a DC voltmeter to measure the rectified AC. Rectified AC is still sine-wave, so a DC voltmeter will not give you an accurate reading.

The addition of the capacitor forces the LEDs to work continuously and, in circuits involving large number of LEDs, heat becomes a problem. In cases where the LEDs are of good quality and operated within the rated current, the biggest factor affecting the life of the LED is heat. Ideally, they should never run over 80oC, but it they are placed close together without ventilation, they could reach over 100oC.

For spotlight use, you may find the 25mA 10mm LEDs, with its tight +/- 6-degree beam-spread more usable.
rob_bisnar5 years ago
Hello qs! its me again. How will you measure the power consumption of this LED series? and How much does each LED consumes in this set-up? thanks in advance!
qs (author)  rob_bisnar5 years ago
Since we know that the MAXIMUM current we allow for is 20mA, then the power consumption is under 2.4-watts. Dividing this by the number of LEDs will give us 57mW per LED for 42 LEDs, or 51mW per for 47.
rob_bisnar5 years ago
Hi qs! I am very thankful for this, it really helps me a lot. I have a question though, you said, the max voltage is about 156V, is this equivalent to the DC voltage level?

I have arranged a bridge rectifier consists of four 1n4003, I measured its output voltage and the meter reads 105Vdc with measured input of 115Vac. Why is it the output is not 115*√2= 163V ?
qs (author)  rob_bisnar5 years ago
The problem with calling what comes out of a full-wave bridge "DC" is the implication that it is the same current as what you might get from batteries.

The real waveform from your bridge, as this image Wikipedia shows is still very much recognisably "AC", except all the sine-waves appear in the same direction (polarity).

That is why you must add a capacitor to + and - to smooth out the "ripples" before your multimeter can recognize it as true "DC".
BridgeRectifier.gif
rob_bisnar qs5 years ago
thank you very much for your response. Does it mean that the reading of 105Vdc is the RMS?
qs (author)  rob_bisnar5 years ago
The meter is expecting a steady input so the reading will depend on the time frame your meter checks to see if the input has changed - the 'Samples/sec' number in the spec sheet.
japanjot5 years ago
in d magic formula 230 * 1.4 / 3.3 , , , , , , 230 is my ac volt, 3.3 is led volt but wot is 1.4 here????? wud b glad if u clear dis to me ...thnx again
qs (author)  japanjot5 years ago
The value reported for AC power is known as the RMS value, which is lower than the peak value. To find the peak value, you have to multiply by sqrt(2), or about 1.4
japanjot qs5 years ago
ohhkkkzzz now i understand,wel u guided me so well, thank u frnd............this means on 230v rms the peak value ud be of 322v................nd one more thing if i connect 49 led's to the 230v ac,and i include a rectifie of max 400v, wt else wud be required more??? a capacitor??? if yes then plz tell of wt value.
qs (author)  japanjot5 years ago
I added step (6) above with the calculation - hope it helps!
japanjot5 years ago
plz help me, m new to this but want to learn alot from you people...... i ant to connect 44 leds in series and want them to work on 230 volts please tell me how can i without burning these leds nd myself 2 :)
qs (author)  japanjot5 years ago
For 230v, the 'magic' number of white LEDs is 230 * 1.4 / 3.3 or 98 LEDs.

This is the number of white LEDs (the same type) that you can connect together in series and operate on 230V-AC without needing resistors or transformers. Just add a suitable bridge rectifier in front.
japanjot qs5 years ago
well thanks alot bro for ur help, but if u don't mind can u also tell me abot bridge rectifier nd its construction nd values.... thank you
qs (author)  japanjot5 years ago
A bridge (full wave) rectifier is simply a package of 4 diodes connected so that regardless of which direction (polarity) an AC voltage is, the + and - always go to separate outputs. Bridge rectifiers have 2 input connections marked (~) and 2 outputs. You have to make sure the specified voltage is higher than the peak voltage and the amperage is greater than what the LEDs draw. You can also make your own bridge by connecting 4 1N4007-type diodes (400V 1A) like in the diagram below.
ACLight200.jpgDiodeBridge.jpg
wkumtrider5 years ago
If I want to run 6 leds off AC, I would need a capacitor to reduce the voltage, correct? What is the best way to calculate the correct type of capacitor? Thanks for your help.
qs (author)  wkumtrider5 years ago
Take a look at the instructions posted here for the correct values.
wkumtrider qs5 years ago
Thanks qs, but I don't quite understand the formual. It has two variables C and X. I'm not sure how to solve the formula with two variables. I must be missing some data.
qs (author)  wkumtrider5 years ago
X is the resistance (reactance) of capacitor, C.

If we know we need a resistance of 7500-ohms at 50Hz, then the correct capacitor value is:

C= 1/(2 x pi x F x X) = 1 / (2 x 3.1415... x 50 x 7500) = 0.424 uF, with 0.47uF as the nearest standard value.