Fixing a Shower Head Heater!

19,896

13

7

Introduction: Fixing a Shower Head Heater!

I bought this brand new heater a few days ago, when I put my multimeter to the wires to test the resistance, I got infinity. What the hell!

Here is how I fixed a brand new heater.

Step 1: The Heater.

This fame Ducha is popular in my country. Very safe once properly grounded. Time to make it ready for installation.

Step 2: Opening the Top.

A flatblade I used to take off the top. Now the switch for hot off lukewarm is exposed.

Step 3: Removing the Switch.

5 Phillips head screws hold the switch in place. Once removed the switch assembly comes off.

Step 4: Verifying the Heater Coils.

I measured the hot and lukewarm coil resistances. These values are expected.

Step 5: Fixing the Contacts.

The spring contacts were not touching their corresponding contacts. This is supposed to be a safety design that allows the heater to be on only when the water pressure is present. For high current switching this arrangement is not ideal and can easily cause arcing plus pitting of the contacts. I want a proper direct connection. Also I made a heater control panel that turns off the heater if no motion is detected inside the shower. Safety wise I'm better covered with my motion sensor system that has been working perfectly for the past 3 years.

I pulled the spring contacts out to ensure low resistance mating.

Step 6: Reassembly and Testing.

Ah ha. Now the leads give a reading per hot and lukewarm settings. Perfect.

Step 7: Completion.

The lid is back on and the heater ready to be installed!

Be the First to Share

    Recommendations

    • Plastic Contest

      Plastic Contest
    • The 1000th Contest

      The 1000th Contest
    • Battery Powered Contest

      Battery Powered Contest

    7 Discussions

    0
    mmnicool
    mmnicool

    Question 7 months ago on Step 7

    How about after that??

    0
    RobertoRams
    RobertoRams

    1 year ago on Step 5

    Please be advised that raising the contacts means that electricity is ALWAYS being applied to the element even if the water isn't running through the unit to prevent it from overheating.

    0
    ReneeG32
    ReneeG32

    Question 1 year ago

    Hi there. I installed my 3 temperature Super Ducha Saturday, however it's only working on the hot/cold setting, not the warm. Any idea what the problem could be and how to fix it.
    Thanks

    0
    InsafK2
    InsafK2

    2 years ago

    Can you post your motion sensor switch used? I would like to try and implement that. Thanks

    1
    OGT1
    OGT1

    Question 2 years ago on Step 5

    What makes the water to heat with motion...mines heat without water present

    0
    wrsexton
    wrsexton

    4 years ago

    Cool, Oh, wait.....

    Not cool! :)

    0
    Mjtrinihobby
    Mjtrinihobby

    Reply 4 years ago

    hot!! Thanks!